hayward blue essence troubleshooting

There is also a faint burnt odor. Im not sure what happened. I have a Heyward VS 500 that suddenly started making a sound like a poker card stuck in your spokes of your bike at all speeds. It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. No lights are coming on as if no power. Probably not cant think of another issue. I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. Likewise, check if the motor is wired correctly for the available field supply voltage. I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. Any idea how to fix this? Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Could also be a loose wire connection, the power wires. hayward blue essence troubleshooting - Habikalli.com I have an older Hayward Pool pump for an above ground pool. "@type": "Person",
Maybe the transformer is not functioning properly? Third, check the back of the motor, the centrifugal switch on the end of the shaft and the stationary switch at 6 oclock to be sure they are tight and aligned tab to tab, and not loose or misaligned. Maybe a complete reboot at the circuit breaker could be the answer, or a reset on the pump control panel. That could explain the pumping problems. "datePublished": "3/27/2015",
The same thing happened to the first one. Third, could be a clog in the main drain or skimmer (suction) pipes. Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. 4 New pump 2 years old. I suspect a loose wire, or mis-wiring or other simple fix. Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. I backwash and rinse and start again but it does the same thing. There should be no elbow after the flow switch. the , . If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. Hello Capt., there is not a thicker o-ring available, but you could possibly seal it up with Blue RTV Silicone, i.e. We live in Arizona, so the automatic freeze setting isnt an issue. If you see any damage, replace your flow switch. Hi Rob, If the pump is the same exact model and horsepower, it sounds like either; 1). Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. I would like to repair it if possible. Hi, could be a lot of things, first I would use a test meter or outlet checker to be sure the outlet has power. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. heres the motor: https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft and the seal: https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2. About two weeks ago, my pool water level was very low and I believe this is were the air bubbles first presented. They do not seem to have enough stooch even though they are rated at 1HP like my original motor. Use a flashlight, and you should see gears moving thru the small view hole. Hello , This is an inactive thread. What do you think? Any ideas on how to fix this issue?? To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. If the motor is still giving you a drive stall error, it probably means that you need a new drive. Hi we have a Hayward DE filter for a 2040 in ground. They disparate as they move through the pool. Alternatively, you can spin the shaft at the rear motor, with a 7/16 wrench inserted behind the stationary switch, on the slotted end of the motor shaft. Something is very loose, or missing, or clamp band threads may be damaged, please be careful people have been fatally injured by pool filter tops popping off under pressure! After the pump and filter are fully drained, screw the plugs back in slightly to keep bugs out, but leave them loose so they will still drain, as needed. Either the pump lid oring is missing, or the lid (cover) is not tight, or a loose threaded pipe coming into the pump, or leaky valves (skimmer, main drain) air leaks are always in front of the pump. I also noticed that the repaired motor Step 2: Did you properly install your switch? Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. I have back washed the filter about 6 times in 1 month, and even soaked the filter (the DE fingers) in a cleaning solution and also soaked it in Muriatic Acid for about 30 minutes. You are using an out of date browser. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). Is my pool pump dead? Home; Events. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? Third time turned off pump same thing happened with humming and eventually kicking in. Be sure that bare wires are not touching other bare wires or terminals, or other metals. 3. loose pipe coming into pump, drawing air around fitting threads If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. Getting air in basket, changed gasket with lube still have the same issue. Products, Learn About The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. $579 + Free Shipping in USA. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. If the capacitor doesnt fix it, you may need a new motor, or pump, barring other issues that can be seen readily. Exterior Wall Covering Materials, Make sure pump motor is set to accept 110V (may be wired to accept 220V), and that all wires for the cord are tight, and connected correctly to terminals L1 and L2, I have a hayward super pump model c48k2n143b1 sp2607x10a and i am trying to wire on the 115v but i dont have a switch to change from 220 or 115 and no diagram on the pump i try yesterday to pump work but was not pulling the water like it is suppose to and after 3 min the pump what very hot .. so i think it is on 220v are you able to help me. Hola Ral, Podra ser una de 4 cosas: encendedor, sensor de fuego, baja presin de gas o el tablero de control. Water temperature is above 140 degrees F. Make sure that either 120VAC or 240VAC input power is connected to the proper screw terminals at the Aqua Rite control. "url": "https://blog.intheswim.com/"
Pressing on/off buttom followed only by click sound of switch. The cell is new. have an old hayward flo lx pump and sounds like it is turning on with a click but wont start sucking the water from the pool through the pump to the filter. My Hayward h250 propane heater keeps blowing fc1 and fc2 fuses immediately after plugging in. The most common places for an air leak on a pump include around the pump lid (must be really tight, with lubed o-ring), or a loose incoming water pipe bringing water (and air) into the pump. Same with other sensors. Pumps need 120V, +/- 10%, so maybe the voltage is fluctuating, from loose connection from breaker to outlet, or a loose breaker. The last one lasted about 3 years. We just verified all our time settings. hayward blue essence troubleshooting - Lyriclifeclothing.com Hi Rob, there could still have been some sand in the pipes yes, and thats probably the problem. Then dunk them in the pool quickly after the acid, to rinse cleanly. No power not even a humming. If it continues, a new o-ring might be the ticket, yes. Seems to take away the point of getting a variable speed pump if we have to run it on high all the time. Check that the shaft spins freely, and check that the triangular switch at 6 oclock in the back of the motor, is tightly screwed, and that the centrifugal switch, located in the center, on the end of the rear shaft, is also tight, and that the two switch tabs are in contact with each other in the center. Is the wire the correct size wire? If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. Thanks Davy. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. The water does not flow when the pump is turned on. I have a Hayward 1.65 variable speed pump it is on a timer for high and low. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. Hi Julie, is the FLO error code on the heater? I just replaced the flow switch and that solved one problem, but now Im only able to produce chlorine when the system is on Super Chlorinate. Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. 2. pump lid gasket or o-ring not lubed, or not positioned properly (superpump) External bypass is out of adjustment. A wire connected to the terminal board may be loose or burnt. OR actually, since you say that it starts good and then loses flow that would be different probably an air leak in front of the pump (pump lid, or the pipe coming into the pump, or leaky suction side valve), or a stuck skimmer weir blocking water flow, or low water level causing a vortex in the skimmer. You need to be really sure about the actual salinity reading. Thank you so much for taking time to answer all our concerns. we bought a hayward super pump for inground pool ever since installing pump we are able to vacuum pool for about 5 minutes then loose suction with filter gauge rising to near 30. if we turn off pump and restart the pump returns to normal with filter gauge registering at 18, we have replaced vacuum hose, checked laterals in filter, checked piping for leaks. Troubleshooting Guides To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. Not sure power goes to the pump. It is being practiced by thousands of pool owners just like you. "@type": "Person",
However, no matter what. I would turn it off and it would hum and eventually start. I currently have Hayward RS750CA and it starts leaking underneath. Additional causes for low water flow in your pump are debris build-up or dirty equipment. Also inspect other wires in the back, look for any pinched wires, or wires touching each other. Is that a reason to replace impeller? The hotel has an excellent location, close to a wonderful coral reef, lagoon with natural pool and sandy beach, outdoor swimming pool available all year round, private beach area, kitesurfing center and bar. Same thing if I try to backwash. how to watch past broadcasts on twitch. But most plastic impellers are closed nowadays, with non-visible vanes. Jake, sounds like you got the filter up to speed. Improving air flow can also help, by trimming bushes or killing weeds, anything to let more breezes into the motor area. I took out the filter cartridge and hosed it down replaced, emptied all the baskets but still no change, only one of the jets is pushing out water, but barely. If it does not, keep reading. Home / Pool Equipment / Pool Pumps / Hayward Pool Pump Troubleshooting. Upon restart, pump sounds horrible, like pumping rocks. Hi John, the cap for that motor is START CAPACITOR, 161-193 MFD (BC-161) we dont carry it, but easily found online. Other problems that could cause this could include a (very) clogged impeller, something actually preventing the shaft from turning or it could be a bad capacitor, a black cylinder in the rear of the motor. Problem is now the pool will not clean up (algae) and the pump is slow to prime. Does it really need to be replaced? If voltage is normal, there may be a loose wire in the motor, perhaps behind the terminal board, or a bent wire that is touching some metal housing, or bent and touching another wire. Kept indoors all off season. Inside there is an o-ring that may be out of position, or need lubricant. If needed, you could replace just the motor, and the shaft seal, and save a few hundred bucks. Blower will operate until error condition is corrected. Capacitor or needs new motor?? If none found, inspect your valve settings, on the equipment pad, and make sure everything is normal, and the cleaner water flow is not being throttled or bypassed. At75%, or lower, in either polarity, it's time to consider replacing the cell. ? I dont think it ran dry, if the pump outlet hose came loose (not the inlet?). What is the problem with those other motors? Any suggestions?? It ran and then we shut it off. Another possible cause is that the impeller is clogged with very small debris. Reassemble pump in reverse order from above. A common mistake is to install the spring seal half backwards. Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? "publisher": {
Also make sure that the pump has no air leaks from loose pipes, loose pump lid, low water level in pool For you Scott, the next step is to shut off power to pump and remove the Blue, Black and Red wires (page 4 owners manual) from the drive and check each motor lead to ground. Wait for the relay to click (5 to 10 seconds). Is there a disconnected wire in the back of the motor? Hi Paul, could it be vibration noise? When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. It is only in its 3rd season. Hi Nancy, Heat Sinks are designed to absorb the heat from the motor, and dissipate it safely. Holy smokes! Breakers do wear out, especially if used often as the pump switch. They are easily replaceable. Pump Surging also occurs from low water level, or air leaks in front of the pump. Wouldnt turn back on for a while even after manually flipping the switch. Do you have any suggestions? "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Lubricating the lid o-ring regularly will help improve the seal. The pump need not be completely air tight, but has to pull more water than air! I removed the back of the pump and the yellow wire has a small black burn hole in it. Many two speed split capacitor motors use the capacitor to boost it to high speed, check the capacitor for bulging, splits, leaking or loose wires, or test for capacitance, or test with new one. My check salt generator station even after I clean it out. are red velvet ants dangerous to dogs stone county, mississippi mugshots disney half marathon 2023 crooked house (2008 trailer) Knowing prime was lost I filled the pool and the filter housing up with water. Just started getting a No Flow error. What is the incoming voltage on a H-150 pool/spa heater ? "keywords": "hayward pool pump",
Hi thanks for speedy reply the breaker is 20 amp with a GFCI. Like it is getting through the shaft seal but the seal is brand new.. any thoughts? It could possibly be a bad cord, or a bad outlet, or loose wires on pump or outlet. I shut the pump down the other night and it will not run. I think I have a different problem with the pump now. I removed the capacitor and had it tested at a local pool store and they told me it was fine. Any ideas why? The electrician also installed w new capacitors on the pump and still same problem. I have purchased a Hayward SP 158015 Power-floLX series 1 1/2 horsepower Above Ground pool pump along with a Hayward S166T Proseries sandfilter 16 inch top mount for a 15 ft above ground proseries pool. Did you rewire the time clock too, or just the pump motor? Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. If there is a little noise, check the motor capacitor, or look at the motor switches in the back, look for anything that looks or smells funny. 9-17-2020 Pump is less than 3 years old. Theres no sound, when we hit the power switch no power. Sometimes it hums but wont start and other times there is nothing. Hi Davy, How Much Salt Belongs In Your Pool of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the Following this procedure will identify Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). Search our blog for shaft seal replacement, if so. An electric motor shop local to you could test them, perhaps for free or low cost. I have an older Haywood super pump 3/4 hp, i replaced it with a new 3/4 hp motor. Or very high mineral content (very hard water), or oily substances. IDXL2DB1930. What can we check. Can u shed any light on what might be the culprit? The pump itself works great. But the clicking, that sounds like a centrifugal switch, on the rear of the shaft, which could be a voltage issue? https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual the first pdf link is the older model H150, the second .pdf link is the newer H150 models, altho it may not make a difference. Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . All-In-One Sanitization If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. Not it says drivererror pump stalled. For AquaRite, move the switch from auto to off and check all of the readings. Hi Bill, when it goes into spa mode, the spa drain valve should open, and close off the pool suction valves, so that all the water is coming into the pump from the spa only. However it is not generating enough chlorine and we are adding chlorine more than we should. Any suggestions? any ideas? Remove the bracket and inspect for bulging, cracking, or burnt marks on the end. 58 amps! Any thoughts? It will start to run normal for 2-3 seconds. Hard pumping can also cause a pump to overheat, but not usually. Motor again started humming and had to repeat the above steps each time I moved to backwash. It just started leaking at the top plumbing connection. I have a Hayward HeatPro model HP21104T. If there is input power, the fuse may have blown. how to watch past broadcasts on twitch. Well, you first need to inspect it, and if the parts are broken, replace them. When running through all these checks and balances if it is noticed that there is not bond wire or that the tightening screws are not all secure, correct the issue. Hi, I have a hayword C48L2N134B3 1.5 HP pool pump. That is the black cylinder in the rear of the motor, located at 9 oclock. Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V.